Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Coluna/Columna ; 15(1): 22-25, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-779075

ABSTRACT

ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°). The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°). There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.


RESUMO Objetivos: Comparar os resultados de tratamento cirúrgico com fixação lombar usando hastes de nitinol sem artrodese e com fixação lombar padrão com hastes de titânio e fusão intersomática. Métodos: Foram analisados os resultados do tratamento em 70 pacientes com escoliose lombar degenerativa com idades entre 40 e 82 anos. Em todos os casos, foram usados parafusos pediculares e hastes de nitinol com diâmetro de 5,5 mm. Trinta pacientes foram submetidos à fixação em L1-S1 e 40 pacientes tiveram fixação em L1-L5. Não foi realizada artrodese da coluna. Todos os pacientes fizeram radiografias, TC e RM. Os resultados foram avaliados de acordo com a escala de Oswestry, com o SRS 22, o SF 36 e EVA. O período mínimo de acompanhamento para todos os pacientes foi de 2,5 anos. No grupo controle, com 72 pacientes, realizou-se a fixação do pedículo com hastes de titânio e fusão intersomática na região lombossacral. Resultados: O nível médio de correção da deformidade correspondeu a 25° (10°-38°). A análise das radiografias e das TC revelou um único paciente com instabilidade, dois pacientes com reabsorção óssea ao redor dos parafusos e um paciente apresentou fraturas da haste. A radiografia funcional 2,5 anos após a cirurgia mostrou mobilidade média da coluna lombar de 21° (15°-30°). Não foram encontrados problemas nos níveis adjacentes. Conclusões: O uso de hastes de nitinol na cirurgia de deformidades da coluna é promissor. Essa tecnologia é uma alternativa à fixação rígida. É preciso manter a coleta continuada de dados clínicos e sua posterior avaliação.


RESUMEN Objetivos: Comparar los resultados de tratamiento quirúrgico con fijación lumbar usando varillas de nitinol sin artrodesis y con fijación lumbar estándar con varillas de titanio y fusión intersomática. Métodos: Fueron analizados los resultados del tratamiento en 70 pacientes con escoliosis lumbar degenerativa con edades entre 40 y 82 años. En todos los casos, fueron usados tornillos pediculares y varillas de nitinol con diámetro de 5,5 mm. Treinta pacientes fueron sometidos a fijación en L1-S1 y 40 pacientes tuvieron fijación en L1-L5. No fue realizada artrodesis de la columna. Todos los pacientes hicieron radiografías, TC y RM. Los resultados fueron evaluados de acuerdo con la escala de Oswestry, con SRS 22, SF 36 y EVA. El período mínimo de acompañamiento para todos los pacientes fue de 2,5 años. En el grupo control, con 72 pacientes, se realizó la fijación del pedículo con varillas de titanio y fusión intersomática en la región lumbosacra. Resultados: El nivel medio de corrección de la deformidad correspondió a 25° (10°-38°). El análisis de las radiografías y de las TC reveló un único paciente con inestabilidad, dos pacientes con reabsorción ósea alrededor de los tornillos y un paciente presentó fracturas de la varilla. La radiografía funcional 2,5 años después de la cirugía mostró movilidad media de la columna lumbar de 21° (15°-30°). No fueron encontrados problemas en los niveles adyacentes. Conclusiones: El uso de varillas de nitinol en la cirugía de deformidades de la columna es promisor. Esa tecnología es una alternativa para la fijación rígida. Es preciso mantener la colecta continuada de datos clínicos y su posterior evaluación.


Subject(s)
Humans , Scoliosis/surgery , Orthopedic Fixation Devices , Internal Fixators , Pedicle Screws
2.
Medisur ; 14(1): 58-63, ene.-feb. 2016.
Article in Spanish | LILACS | ID: lil-777039

ABSTRACT

Las fracturas distales del radio se presentan con gran frecuencia en la práctica médica. En nuestro medio es posible que no contemos en un momento determinado con los dispositivos más usados para la fijación de estas fracturas, por esta razón debemos tener en cuenta todas las posibles combinaciones a nuestro alcance para solucionarlas ya que la mayoría de las veces no es posible mantener una reducción de estas con una sola técnica. Por tales razones se presenta el caso de una paciente de 24 años de edad, atendida en el Hospital General Universitario Dr. Gustavo Aldereguía Lima, de Cienfuegos, debido a una fractura articular distal, desplazada, del radio de su mano izquierda, producida por impactación y que fue estabilizada mediante el empleo de la combinación de fijación interna mediante placas y tornillos y minifijador externo RALCA® con resultados satisfactorios.


Distal radius fractures are very common in medical practice. In our service, we may not have the most widely used devices for fixation of these fractures at a given moment. For this reason, we must consider all possible combinations within our power to correct them since most of the time, it is impossible to maintain a fracture reduction using a single technique. We present the case of a 24-year-old female patient treated at the Dr. Gustavo Aldereguía Lima University General Hospital in Cienfuegos due to a displaced fracture of the left distal radius caused by impaction. It was successfully stabilized by internal fixation with plates, screws and the RALCA® external mini-fixator.

3.
Coluna/Columna ; 12(2): 119-123, 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-680726

ABSTRACT

OBJETIVO: Evaluar a un año el resultado del uso de espaciadores dinámicos en listésis grado I de Meyerding utilizando la escala de incapacidad de Oswestry. MÉTODOS: Se revisa el historial electrónico y radiográfico de los pacientes según criterios en el período de enero 2008 a diciembre 2010, con el propósito de realizar un estudio de cohortes, retrospectivo, longitudinal y observacional. RESULTADOS: El Oswestry prequirúrgico fue de 3.4% leve, 55.2% moderado y 41.4% severo; mientras que el posquirúrgico fue de 79.3% leve y 20.7% moderado. La cirugía realizada más común fue exploración y liberación con un 72.4%, presentando discectomía únicamente el 27.6%. Los pacientes presentaron dolor irradiado a miembro pélvico derecho en el 37.9%, miembro pélvico izquierdo 44.8% y a ambos miembros pélvicos en un 17.2%. Se presentó dolor posquirúrgico irradiado a miembro pélvico únicamente en el 2.4% siendo que el 100% de los casos presentaron algún tipo de dolor irradiado. Se utilizó espaciador DIAM en 79.3% y Wallis en 20.7% CONCLUSIONES: El tratamiento con espaciador interespinoso presenta un bajo índice de reintervención y por lo menos a un año presenta mejoría significativa en el índice de incapacidad.


OBJETIVO: Avaliar o resultado em ano do uso de espaçadores dinâmicos em listese de grau I de Meyerding, utilizando a escala de incapacidade de Oswestry. MÉTODOS: Foi revisado o prontuário eletrônico e as radiografias dos pacientes, de acordo com os critérios, no período de janeiro de 2008 a dezembro de 2010, visando realizar um estudo de coortes, retrospectivo, longitudinal e observacional. RESULTADOS: O índice de Oswestry pré-cirúrgico foi de 3,4% leves, 55,2% moderados e 41,4% graves, enquanto o pós-cirúrgico foi de 79,3% leves e 20,7% moderados. A cirurgia mais realizada foi exploração e liberação, em 72,4%, sendo que 27,6% apresentaram apenas discectomia. Os pacientes tinham dor irradiada para o membro inferior direito em 37.9%, para o membro inferior esquerdo em 44,8% e para ambos os membros inferiores, em 17,2%. Verificou-se dor pós-operatória irradiada para o membro inferior só em 2,4%, sendo que 100% dos casos tinham algum tipo de dor irradiada. Foi empregado o espaçador DIAM em 79.3% e o Wallis em 20.7% CONCLUSÕES: O tratamento com espaçador interespinhoso apresenta baixo índice de re-intervenção e pelo menos em um ano, apresenta melhora significante do índice de incapacidade.


OBJECTIVE: To evaluate one-year results of using dynamic spacers in listhesis grade I of Meyerding using Oswestry Disability Index. METHODS: The disability scale review was based in the electronic and radiographic history of patients according to criteria in the period from January 2008 to December 2010, in order to conduct a cohort study, retrospective, longitudinal, and observational. RESULTS: The Oswestry index before surgery was 3.4% mild, 55.2% moderate and severe 41.4%, while the postoperative was 79.3% mild and 20.7% moderate. The most common surgery performed was exploration and release in 72.4%, and only 27.6% had discectomy. Patients had pain radiating to right lower limb in 37.9%, to the left lower limb in 44.8% and to both lower extremities in 17.2%. Pain radiating to the lower limb after surgery was found only in 2.4%, and 100% of the cases had some type of radiating pain. The DIAM interspinous implant was used in 79.3%, and the Wallis in 20.7%. CONCLUSIONS: Treatment with interspinous spacer has a low rate of reoperation and at least during one year presented significant improvement in the rate of disability.


Subject(s)
Humans , Internal Fixators , Spine/surgery , Spondylolisthesis , Low Back Pain
4.
Coluna/Columna ; 11(3): 195-199, July-Sept. 2012. ilus
Article in English | LILACS | ID: lil-654879

ABSTRACT

OBJECTIVE: The aim was to determine in vivo whether pre-operative mobility of the lumbar spine (overall and segmental) is retained after surgical intervention. METHODS: Functional imaging of the lumbar spine was performed in flexion and extension, using a lateral projection under standardised conditions. This allowed assessment of the overall mobility, mobility of the instrumented mobile segments and the disc height of the adjacent cranial segment (intervertebral space; IVS) before and after surgical intervention. Images were evaluated independently by a radiologist and an orthopaedic surgeon. A comparative analysis of preoperative and postoperative functional images was carried out with the aid of a computer and appropriate software (ACES) for further assessment of the extent to which the range of movement was retained. The Oswestry Disability Index (ODI, quality of life assessment) and the visual analogue scale (VAS, pain assessment) were used as clinical criteria and compared pre-and postoperatively. The mean follow-up (FU) intervals were 13.5 days (FU 1) and 19 months (FU 2). RESULTS: Radiological results showed that the overall mobility of the lumbar spine (L1 to S1) decreased on average by one third of the flexion/extension range, from 25.0º preoperatively to 17.6º postoperatively. The segmental mobility of the monosegmental stabilisation decreased on average from 3.7º to 2.3º. The caudal segments of the bisegmental dynamic stabilisation retained their preoperative movement range of 2.6º, with a postoperative range of 2.4º. The IVS did not change. The ODI improved postoperatively from 59 (preoperative) to 39/41 (FU1/FU2) points, while the VAS (during movement) improved from 7.6 (pre-op) to 4.4/4.5 (FU1/FU2). Computer-assisted analysis showed that small and functionally insignificant micro-motion of 0.4º (error 0.12%) remained in the stabilised and unfused mobile segment. CONCLUSION: Comparison of preoperative and postoperative measurements showed that overall mobility and segmental micro-motion were retained after non-fusion stabilisation of the lumbar spine with monosegmental and bisegmental instrumentation. The adjacent cranial segment (IVS) did not collapse. Activity levels (ODI) and pain symptoms (VAS) of the patients showed significant improvement at follow-up, comparable to that reported in the literature for conventional rigid spinal fusions.


OBJETIVO: O objetivo foi determinar in vivo se a mobilidade pré-operatória da coluna lombar (geral e segmentar) é mantida depois da intervenção cirúrgica. MÉTODOS: Foram realizadas imagens funcionais da coluna lombar em flexão e extensão, usando projeção lateral em condições padronizadas. Isso permitiu a avaliação da mobilidade geral, da mobilidade dos segmentos móveis instrumentados e da altura do disco do segmento rostral adjacente (espaço intervertebral; IVS) antes e depois da intervenção cirúrgica. As imagens foram analisadas independentemente por um radiologista e por um cirurgião ortopedista. Realizou-se análise comparativa das imagens funcionais pré e pós-operatórias com o auxílio de computador e de software apropriado (ACES) para avaliar mais detalhadamente a extensão em que a amplitude de movimento foi mantida. O Oswestry Disability Index (ODI, avaliação da qualidade de vida) e a escala visual analógica (VAS, avaliação da dor) foram usadas como critérios clínicos e comparadas no pré e pós-operatório. Os intervalos médios de acompanhamento (FU, de follow-up) foram 13,5 dias (FU 1) e 19 meses (FU 2). RESULTADOS: Os resultados radiológicos mostraram que a mobilidade geral da coluna lombar (L1 a S1) diminuiu, em média, um terço na amplitude de flexão e extensão, de 25,0º antes da cirurgia, para 17,6º depois. A mobilidade dos segmentos na estabilização monossegmentar diminuiu, em média, de 3,7º para 2,3º. Os segmentos caudais da estabilização dinâmica bissegmentar mantiveram a amplitude de movimento pré-cirúrgica de 2,6º, chegando até 2,4º depois da cirurgia. O IVS não foi alterado. O ODI melhorou depois da intervenção, de 59 para 39/41 (FU 1/FU 2) pontos, enquanto a VAS (durante movimento) melhorou de 7,6 (pré-operatório) para 4,4/4,5 (FU 1/FU 2). A análise auxiliada por computador mostrou que o pequeno e funcionalmente insignificante micromovimento de 0,4º (erro de 0,12%) permaneceu no segmento móvel estabilizado com técnica de não-fusão. CONCLUSÃO: A comparação das mensurações pré e pós-operatórias mostrou que a mobilidade geral e o micromovimento segmentar foram mantidos depois de estabilização da coluna lombar com técnica de não-fusão, com instrumentação mono e bissegmentar. O segmento rostral adjacente (IVS) não sofreu colapso. Os níveis de atividade (ODI) e os sintomas dolorosos (VAS) dos pacientes apresentaram melhora significante no acompanhamento, comparável aos relatados na literatura referentes às fusões espinais rígidas convencionais.


OBJETIVO: Fue determinar in vivo si la movilidad preoperatoria de la espina lumbar (general y segmentaria) se mantiene después de la intervención quirúrgica. MÉTODOS: La representación por imágenes de la espina lumbar se realizó en flexión y extensión, usándose una proyección lateral en condiciones estandarizadas. Esto permitió la evaluación de la movilidad general, la movilidad de los segmentos móviles instrumentados y la altura de disco del segmento craneano adyacente (espacio intervertebral; IVS), antes y después de la intervención quirúrgica. Las imágenes fueron evaluadas, independientemente, por un radiólogo y un cirujano ortopedista. Un análisis comparativo de las imágenes funcionales preoperatorias y posoperatorias fue realizado con la ayuda de una computadora y del software apropiado (ACES) para evaluación adicional de la extensión hasta la cual se mantuvo la amplitud del movimiento. El Índice de Incapacidad de Oswestry (ODI, evaluación de la calidad de vida) y la escala análoga visual (VAS, evaluación del dolor) fueron usados como criterios clínicos y comparados antes y después de la cirugía. Los intervalos promedio de seguimiento (FU) fueron 13,5 días (FU 1) y 19 meses (FU 2). RESULTADOS: Los resultados radiológicos muestran que la movilidad general de la espina lumbar (L1 a S1) se redujo, en promedio, en un tercio de la amplitud de flexión/extensión, de 25,0º antes de la cirugía a 17,6º después de la cirugía. La movilidad segmentaria, de la estabilización monosegmentaria, disminuyó, en promedio, de 3,7º a 2,3º. Los segmentos caudales de la estabilización dinámica bisegmentaria mantuvieron su amplitud de movimiento preoperatorio de 2,6º, con una extensión de 2,4º después de la cirugía. El IVS no cambió. El ODI mejoró después de la cirugía de 59 (preoperatorio) puntos a 39/41 (FU1/FU2), mientras que la VAS (durante el movimiento) mejoró de 7,6 (preoperatoria) a 4,4/4,5 (FU1/FU2). El análisis, con ayuda de la computadora, mostró que un pequeño micromovimiento, funcionalmente insignificante, de 0,4º (error 0,12%) permaneció en el segmento móvil estabilizado y no fusionado. CONCLUSIÓN: La comparación de las mediciones preoperatoria y posoperatoria mostró que la movilidad general y el micromovimiento segmentario fueron mantenidos después de la estabilización no fusionada de la espina lumbar con instrumentación monosegmentaria y bisegmentaria. El segmento craneano adyacente (IVS) no tuvo un colapso. Los niveles de actividad (ODI) y los síntomas de dolor (VAS) de los pacientes mostraron mejoría significativa en el seguimiento, comparable a la que se informa en la literatura para fusiones espinales convencionales, rígidas.


Subject(s)
Humans , Bone Screws , Spine , Radiography , Lumbosacral Region
5.
Coluna/Columna ; 11(1): 24-28, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-623154

ABSTRACT

OBJETIVO: Avaliação da evolução radiográfica da lesão da coluna vertebral cervical tratada pela fixação posterior isolada. MÉTODOS: De 2000 a 2008 foram selecionados 23 pacientes que atenderam aos critérios de inclusão do estudo. Eram masculinos 91,3% e a idade média foi de 34 anos e quatro meses. O tempo de seguimento médio foi de 82 meses. Foi avaliado no exame de imagem pré-operatório, pós-operatório imediato e após seis meses de evolução o tipo de implante, a consolidação da artrodese, se houve soltura do implante, perda de redução, cifose segmentar, degeneração de nível adjacente e pseudartrose. RESULTADOS: Em relação ao método de síntese, 60,8% dos pacientes foram submetidos ao amarrilho interespinhoso, 26% à placa com parafusos de massa lateral e 13% à barra com parafusos de massa lateral. Dos pacientes submetidos à fixação com parafusos, nenhum apresentou complicações radiográficas e 35,7% dos pacientes submetidos à artrodese com amarrilho interespinhoso tiveram complicação, sendo a mais frequente a cifose segmentar. CONCLUSÃO: As lesões da coluna cervical submetidas a artrodese com parafuso de massa lateral apresentaram uma evolução radiográfica melhor do que as submetidas a fixação com amarrilho interespinhoso, tendo este último apresentado maior incidência de complicações na artrodese.


OBJECTIVE: To perform a radiographic evaluation of the cervical spine injury treated with posterior fixation techniques only. METHODS: From 2000 to 2008, twenty three patients were included in the study, of which 91,3% were men, with a mean age of thirty-four years and four months. The mean follow-up time was 82 months. The type of implant used, the radiographic arthrodesis consolidation, implant failure, lost of reduction, segmental kyphosis and pseudarthrosis were evaluatedin the preoperative period, the immediate postoperative period and after six months of evolution, based on the patients records. RESULTS: When it comes to the type of implant used, there were 60,8% of the patients who underwent interspinous wire fixation, 26% with lateral mass screws and plate and 13% with lateral mass screws and rods. Of the lateral mass screws patients, none had radiographic complications and 35,7% of the interspinous wire patients had complications being the segmental kyphosis the most frequent of them. CONCLUSIONS: The cervical spine injuries that underwent lateral mass screw fixation showed better radiographic results, with less complications than the interspinous wire fixation.


OBJETIVO: Evaluación de la evolución radiológica de la lesión de la columna cervical tratada con fijación posterior aislada. MÉTODOS: De 2000 a 2008, se seleccionaron 23 pacientes que cumplían los criterios de inclusión del estudio. 91,3% eran varones y la edad media fue de 34 años y cuatro meses. El período de seguimiento promedio fue 82 meses. Se evaluó, en los exámenes de imágenes antes de la cirugía, inmediatamente después de la operación y después de seis meses de evolución, el tipo de implante, la consolidación de la artrodesis, si había aflojamiento del implante, la pérdida de la reducción, la cifosis segmentaria, la degeneración de nivel adyacente y la pseudoartrosis. RESULTADOS: En comparación con el método de síntesis, 60,8% de los pacientes se sometieron a fijación por cableado interespinoso, 26% a la placa con tornillos de masa lateral y 13% a la barra con tornillos de masa lateral. De los pacientes sometidos a fijación con tornillos, ninguno presentó complicaciones radiográficas y 35,7% de los pacientes sometidos a la fusión con el cableado interespinoso presentaron complicaciones, siendo la cifosis segmentaria la más frecuente. CONCLUSIÓN: Las lesiones de columna cervical sometidas a la fusión con el tornillo de masa lateral presentaron una evolución radiográfica mejor que las de quienesfueron sometidos a fijación con cableado interespinoso, esta última presentó una mayor incidencia de complicaciones en la artrodesis.


Subject(s)
Cerclage, Cervical , Cervical Vertebrae , Fracture Fixation , Internal Fixators , Orthopedic Fixation Devices , Spinal Fractures , Spinal Injuries
6.
Coluna/Columna ; 9(2): 126-131, abr.-jun. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-557031

ABSTRACT

Avaliar a correção da cifose, da altura do corpo vertebral e da redução dos fragmentos retropulsados nas fraturas toracolombares tipo explosão por ligamentotaxia. MÉTODOS: estudo retrospectivo avaliando um total de 238 pacientes com fraturas toracolombares tipo explosão do grupo A3 pela classificação de Magerl et al., dos quais 63 deles elegíveis para a pesquisa. Todos foram tratados com fixador interno pedicular e tinham imagens radiográficas e tomográficas pré e pós-operatórias. RESULTADOS: No estudo, foi constatada, no pós-operatório imediato, uma correção da cifose vertebral no local da fratura de 87 por cento, com correção de 51 por cento na altura do corpo vertebral e redução de 40 por cento dos fragmentos retropulsados intracanal. CONCLUSÕES: o uso de fixador interno por via posterior permite, ao realizar ligamentotaxia, a restauração da altura do corpo vertebral fraturado, do alinhamento sagital da coluna e descompressão do canal espinhal, minimizando as comorbidades em relação à cirurgia pela via anterior e à laminectomia para descompressão do canal.


To evaluate the correction of kyphosis, of the vertebral body height and the reduction of the retropulsed fragments in the thoracolumbar burst fractures by means of ligamentotaxis. METHODS: retrospective study evaluating a total of 238 patients with thoracolumbar A3 burst fractures based on the classification by Magerl et al., of which 63 were eligible to the research. All patients had been treated with pedicular internal fixation and had previous and postoperative radiographs and computed tomographic images. RESULTS: the study evidenced an immediate postoperative correction of vertebral kyphosis in the fracture site in 87 percent of the cases, with correction of 51 percent in the vertebral body height and reduction of 40 percent the intra-canal retropulsed fragments. CONCLUSIONS: the use of internal fixation by anterior approach allows, through ligamentotaxis, the restoration of the height of the vertebral body fracture, of the sagittal alignment of the column and spinal canal decompression, thus minimizing the comorbidities in relation to the surgery by anterior approach and laminectomy to canal decompression.


Evaluar la corrección de la cifosis, de la altura del cuerpo vertebral y de la reducción de los fragmentos retro pulsados en las fracturas toracolumbares tipo explosión por ligamentotaxia. MÉTODOS: estudio retrospectivo evaluando un total de 238 pacientes con fracturas toracolumbares tipo explosión del Grupo A3 por la clasificación de Magerl et al., de los cuales 63 de ellos fueron elegidos para la investigación. Todos fueron tratados con fijador interno pedicular y tenían imágenes radiográficas y de tomografías pre y postoperatorias. RESULTADOS: en el estudio, se constató en el postoperatorio inmediato una corrección de la cifosis vertebral en el local de la fractura de 87 por ciento con corrección de 51 por ciento en la altura del cuerpo vertebral, y una reducción de 40 por ciento de los fragmentos retro pulsados intracanal. CONCLUSIONES: el uso del fijador interno por vía posterior permite, al realizar ligamentotaxia, la restauración de la altura del cuerpo vertebral fracturado, del alineamiento sagital de la columna y descompresión del canal espinal minimizando la comorbidad en relación a la cirugía por vía anterior y la laminectomía para descompresión del canal.


Subject(s)
Kyphosis/surgery , Spinal Fractures/surgery , Internal Fixators , Longitudinal Ligaments , Spinal Canal
7.
Coluna/Columna ; 8(1): 1-6, jan.-mar. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-538650

ABSTRACT

Avaliar a influência da reconstrução e fixação anterior no desempenho mecânico do fixador interno da coluna vertebral. MÉTODOS: foram formados três grupos experimentais de acordo com a reconstrução e fixação anterior: grupo I -sem suporte anterior; grupo II - com suporte anterior; grupo III - com suporte e fixação anterior. Os corpos de prova foram submetidos a ensaios mecânicos de flexo-compressão, flexão lateral e torção, realizados em máquina de universal de ensaios, tendo sido realizados dez ensaios para cada modalidade (flexo-compressão, flexão lateral e torção) em cada grupo experimental, perfazendo um total de 90 ensaios mecânicos. As propriedades mecânicas estudadas foram: o momento-fletor, o torque e a rigidez obtidos a partir da curva carga x deflexão de cada ensaio mecânico. RESULTADOS: observou-se que a colocação do suporte e da fixação anterior aumentou a resistência mecânica nos ensaios de flexo-compressão. Nos ensaios de flexão lateral observou-se aumento da resistência mecânica somente com a fixação anterior. CONCLUSÃO: nos ensaios de torção o suporte anterior e a fixação anterior não aumentaram a resistência mecânica do sistema de fixação vertebral.


Evaluation of the mechanical stability of the internal vertebral fixation through the influence of the anterior load bearing reconstruction and stabilization. METHODS: cylindrical woods blocks were utilized as test bodies and were stabilized by an internal fixation. Three experimental groups were set according to the anterior reconstruction and fixation: group I - without anterior support; group II - with anterior support and group III - with support and anterior fixation. In an universal assay machine the wood block underwent to flexion-compression, lateral flexion and torsion mechanical assays, until ten assays of each modality were performed (flexion-compression, lateral compression and torsion) in each experimental group, in a total of 90 mechanical assays. The studied mechanical proprieties were the flex moment, torsion moment and the stiffness, obtained through the load x deflection of each mechanical trial. RESULTS: it was observed that utilizing a support and anterior fixation there has been na increased mechanical stiffness in the flexion-compression mechanical assays. In the lateral flexion tests it was observed an increased rigidity only with the anterior fixation. CONCLUSION: with the torsion tests the anterior support and fixation did not increase the mechanical rigidity of the vertebral fixation system.


Evaluar la influencia de la reconstrucción y fijación anterior en el desempeño mecánico del fijador interno de la columna vertebral. MÉTODOS: fueron formados tres grupos experimentales de acuerdo com la reconstrucción y fijación anterior: grupo I- sin soporte anterior, grupo II- con soporte anterior y grupo III- con soporte y fijación anterior. Los cuerpos de prueba fueron sometidos a ensayos mecánicos de flexocompresión, flexión lateral y torción, realizados en la máquina universal de ensayos, habiéndose realizados 10 ensayos para cada modalidad (flexocompresión, flexión lateral y torción) en cada grupo experimental,con untotal de 90 ensayos mecánicos. Las propiedades mecánicas estudiadas fueron el momento-flexor, la torción y la rigidez obtenidas a partir de la curva carga x deflexión de cada ensayo mecánico. RESULTADOS: fue observado que la colocación del soporte y de la fijación anterior aumentaron la resistencia mecánica en los ensayos de flexo-compresión. En los ensayos de flexión lateral fue observado aumento de la resistencia mecánica solamente con la fijación anterior. CONCLUSIÓN: en los ensayos de torción, el soporte anterior y la fijación anterior no aumentaron la resistencia mecánica del sistema de fijación vertebral.


Subject(s)
Humans , Biomechanical Phenomena , Dystonia Musculorum Deformans , Internal Fixators , Orthopedic Fixation Devices , Spine , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL